Doct Fix - Clevis Hanger

Ø Pipe Rod Center Height Cross Bolt Stock Max. Load
Size Available Size-A Line-B C G H Kgs.
1/2" 20-25 3/8" 44 55 1/4" 3 x 25 3 x 25 270
3/4" 26-30 3/8" 54 68 1/4" 3 x 25 3 x 25 270
1" 32-36 3/8" 58 75 1/4" 3 x 25 3 x 25 270
1-1/4" 38-43 3/8" 80 100 1/4" 3 x 25 3 x 25 270
1-1/2" 47-51 3/8" 81 106 1/4" 3 x 25 3 x 25 270
2" 60-64 3/8" 86 117 1/4" 3 x 25 3 x 25 270
2-1/2" 75-80 1/2" 106 144 5/16" 3 x 32 3 x 32 500
3" 87-92 1/2" 127 172 5/16" 3 x 32 3 x 32 500
4" 113-118 5/8" 141 199 3/8" 4 x 32 3 x 32 640
5" 138-142 5/8" 159 229 3/8" 4 x 32 3 x 32 640
6" 159-166 3/4" 174 257 1/2" 4 x 38 3 x 38 800
8" 207-219 7/8" 212 320 5/8" 5 x 45 4 x 45 900
10" 260-273 7/8" 250 387 5/8" 6 x 45 5 x 45 1600
12" 309-323 7/8" 292 457 5/8" 6 x 50 5 x 50 1700

Pipe Hanger- Adjustable Swivel Ring / Pear Clamp - Zinc Plated With Knurled Nut

Tube Size Available Ø H Sheet Size
Inches Size (MM) Size (MM) MM
3/4" 20 64 1.5 x 25
1 25 72 1.5 x 25
1 1/4" 32 83 1.5 x 25
1-1/2" 40 96 1.5 x 25
1-1/2" 40 96 1.5 x 25
2 50 113 1.5 x 25
2 1/2" 65 132 20 x 25
3 80 156 20 x 25
4 100 215 20 x 25
5 125 242 2.5 x 25
6 150 279 2.5 x 25

Rod Hanger - Pre-Cast System

Performance Load depends on accurate hole diameter so ensure that drill bits are in good condition and of the correct size. Embedment solid be at 90º to mounting surface.
Tensile Loads
Base Material Shank Diameter mm Hole Diameter mm Installation Embedment Depth mm Ultimate Load Kn Characteristic Load Kn Rec. Tensile Load Kn
Dense Concrete (40 N/mm²) 6 6 40 6.4 4.1 1.5
Dense Concrete (20 N/mm²) 6 6 40 4.9 2.9 1.0
Lightweight Concrete (40 N/mm²) Portland Cement with Lytag Aggregate 6 6 40 3.9 2.6 0.9
Lightweight Concrete (40 N/mm²) Portland Cement with Lytag Aggregate 6 6 40 3.9 2.6 0.9
Lightweight Concrete (40 N/mm²) Portland Cement with Lytag Aggregate 6 6 40 3.4 2.5 0.8

 

Temperature: All steel construction gives stable performance over a wide temperature range.

Spacing

Placing anchor closer together or closer to unsupported edges that the recommended distance can reduce performance

Guidelines should be observed

  • Between centres

    To achieve loads shown, anchor should be 12 x bolt diameter apart. Absolute minimum is 6 x bolt diameter, achieving 50% of loads shown. Do not space anchors closer than this.

  • From edge

    To achive loads shown, anchor should be 9 x bolt diameter from edge. Absolute minimum is 3 x bolt diameter, to achieve 50% of loads shown. Do not place closer than this.

Size Available

Size Available Dimensions (MM) Thread Weight
A B C D E Kg / 100
12 x 50 50 17 23 9.5 12 5.5
14 x 54 54 19 26 11.5 14 7.5
16 x 61 61 23 28 14 16 10.7
18 x 70 70 24 35 14.5 18 18.5
20 x 73 73 28 36 16.5 20 22.0
24 x 86 86 32 44 19 24 20.2
30 x 107 107 29 57 22.5 30 51.8

U-Bolt Electro Galvanized With Two Nuts

Tube Size Available A B C
M6 x 1/2" 17.3 39.3 20
M6 x 5/8" 21.7 41.7 20
M6 x 3/4" 27.2 47.2 20
M6 x 1" 34.0 54.0 20
M6 x 1 1/4" 42.7 62.7 20
M6 x 1 1/2" 48.6 68.6 20
M6 x 2" 60.5 80.5 20
M6 x 2 1/2" 77.0 97.0 20
M6 x 3" 90.0 111.0 20
M8 x 1/2" 17.3 42.3 25
M8 x 5/8" 21.7 46.7 25
M8 x 3/4" 27.2 52.2 25
M8 x 1" 34.0 59.0 25
M8 x 1 1/4" 42.7 67.7 25
M8 x 1 1/2" 48.6 73.6 25
M8 x 2" 60.5 85.5 25
M8 x 2 1/2" 77.0 102.0 25
M8 x 3" 90.0 116.0 25
M8 x 4" 116.0 140.0 25
M10 x 1/2" 17.3 47.3 30
M10 x 5/8" 21.7 51.7 30
M10 x 3/4" 27.2 57.2 30
M10 x 1" 34.0 64.0 30
M10 x 1 1/4" 42.7 72.7 30
M10 x 1 1/2" 48.6 78.6 30
M10 x 2" 60.5 90.5 30
M10 x 2 1/2" 77.0 107.0 30
M10 x 3" 90.0 121.0 30
M10 x 4" 116.0 140.0 30
M10 x 5" 142.0 175.0 30
M10 x 6" 170.0 198.0 30
M12 x 2" 60.5 101.0 35
M12 x 2 1/2" 77.0 117.0 35
M12 x 3" 90.0 129.0 35
M12 x 4" 116.0 145.0 35
M12 x 5" 142.0 159.0 35
M12 x 6" 170.0 182.0 35
M12 x 8" 220.0 248.0 35
M12 x 10" 270.0 300.0 35
M12 x 12" 320.0 354.0 35

Weldless Eye Nut Auto Black - HDG

Size Available R A B C D E F G
3/8" 20 52 13 32 38 25 34.5
1/2" 20 52 13 32 38 25 34.5
5/8" 20 52 13 32 38 25 34.5
3/4" 20 52 13 32 38 25 34.5
7/8" 26 66.7 19 42.9 50 31 50
1" 26 66.7 19 42.9 50 31 50
1 1/8" 32 86 25.4 57 63.5 47 62
1 1/4" 32 86 25.4 57 63.5 47 62
1 1/2" 32 86 25.4 57 63.5 47 62

Wire Hanger - Pre-Cast System

Performance Load depends on accurate hole diameter so ensure that drill bits are in good condition and of the correct size. Embedment shoild be at 90º to mounting surface.
Tensile Loads
Base Material Shank Diameter mm Hole Diameter mm Installation Embedment Depth mm Ultimate Load Kn Characteristic Load Kn Rec. Tensile Load Kn
Dense Concrete (40 N/mm²) 6 6 40 6.4 4.1 1.5
Dense Concrete (20 N/mm²) 6 6 40 4.9 2.9 1.0
Lightweight Concrete (40 N/mm²) Portland Cement with Lytag Aggregate 6 6 40 3.9 2.6 0.9
Lightweight Concrete (40 N/mm²) Portland Cement with Lytag Aggregate 6 6 40 3.4 2.5 0.8

 

Temperature: All steel construction gives stable performance over a wide temperature range.

Spacing

Placing anchor closer together or closer to unsupported edges that the recommended distance can reduce performance

Guidelines should be observed

  • Between centres

    To achieve loads shown, anchor should be 12 x bolt diameter apart. Absolute minimum is 6 x bolt diameter, achieving 50% of loads shown. Do not space anchors closer than this.

  • From edge

    To achive loads shown, anchor should be 9 x bolt diameter from edge. Absolute minimum is 3 x bolt diameter, to achieve 50% of loads shown. Do not place closer than this.

Size Available

Size Available Dimensions (MM) Weight
A B C D E F G H I J K Kg / 100  
M6 x 35 6 8 13 14 8 9 6.3 7 15 1.2 35 0.75
M8 x 40 8 9 17 16 10.5 12 8.3 9 10 1.5 40 1.10
M8 x 53 8 9 17 16 10.5 12 8.3 9 23 1.5 53 1.50
M10 x 45 10 10 20 18 12.5 14 10.3 10 15 1.5 45 1.50
M10 x 57 10 10 20 18 12.5 14 10.3 10 25 1.5 57 2.00
M12 x 55 12 12 23 21 14 16 12.3 12 20 1.5 55 2.60
M12 x 78 12 12 23 21 14 16 12.3 12 43 1.5 78 3.90
M12 x 62 12 15 24 25 15 18 12.3 12 25 2 62 4.05
M14 x 80 14 16 27.5 26 16.5 20 12.3 13 33 2 80 6.40
M16 x 80 16 20 32 30 20 22 12.3 15 30 2.5 80 10.00
M16 x 100 16 20 32 30 20 22 12.3 15 50 2.5 100 12.80
M16 x 120 16 20 32 30 20 22 12.3 15 30 2.5 120 15.50
M20 x 95 20 22 40 37 24.5 28 14.3 18 28 3 95 16.50
M20 x 115 20 22 40 37 24.5 28 14.3 18 50 3 115 20.10
M24 x 120 24 35 47 45 29 32 14.3 21 40 3.5 120 27.90
M27 x 150 27 39 55 54 32 38 21 38 42 4 150 41.00

Installation

  • Drill 6mm hole and Tap Wire hanger home
  • Insert sharped end of setting tool into Wire hanger's suspension hole. Using tool as lever, withdraw Wire hanger as far as possible.
  • Attach the wire
Send Your Requirement